The grease interceptor is one of the first plumbing decisions in a restaurant fit-out and one of the most expensive to get wrong. Too small, and it fills in days, grease passes into the sewer, and you are paying for pump-outs and drain jetting for as long as you hold the lease. Too large or badly placed, and it costs more to install, is harder to service, and can still fail inspection. Getting the size right before the floor is cut saves money for years.

This guide is for restaurant owners, franchise operators and landlords planning a new kitchen or taking over an existing one in Ontario. It explains how grease interceptors are sized, the difference between hydromechanical and gravity units, what the Ontario Building Code and the CSA standards require, a worked example, and the fit-out questions to ask before you sign off the plans. It is a planning guide, not a substitute for sizing on your actual drawings by a licensed plumber or designer.

The short answer

A grease interceptor is sized in two steps:

  1. Flow. Add up the water that can drain into it at once, mostly from the sinks, and divide by how fast it drains. That gives a peak flow rate. Choose a unit rated at or above that flow.

  2. Grease capacity. Check that the unit can hold the grease your menu produces between cleanings. A unit that handles the flow but fills in a week is still undersized for a fryer-heavy kitchen.

Small and mid-size kitchens usually use a hydromechanical interceptor sized by flow. Large kitchens, food courts and buildings with several food tenants usually need a gravity interceptor sized by volume.

The rules in Ontario

Three layers apply to a new interceptor in Ontario:

  • The Ontario Building Code requires the interceptor where commercial food preparation discharges grease, and says a required interceptor must conform to CSA B481.1 (tested with lard) or CSA B481.2 (tested with oil).

  • The CSA B481 series sets how interceptors are tested and rated, and CSA B481.3 covers their sizing, selection, location and installation. The series was revised in 2021, so make sure your designer is working to the current edition (CSA Group).

  • Your municipality adds permits and sewer use rules. The City of Toronto requires a building permit to install or replace a grease interceptor and notes there is no CSA standard for gravity interceptors, which are sized to the Building Code (City of Toronto). In Kitchener, Waterloo and Cambridge, food businesses discharging fats, oils and grease need a permit under the Region of Waterloo Sewer Use By-law 21-036.

Read the label before you buy. Units certified to CSA B481.1:22 are marked with their flow rating, grease removal efficiency, maximum grease capacity, inlet size and the flow control device they need. Those markings are the numbers you size against.

Plumber tightening the flow control fitting between a three-compartment sink and a hydromechanical grease interceptor

Hydromechanical vs gravity: which type do you need?

Hydromechanical interceptor

Gravity grease interceptor

What it is

Compact unit with internal baffles, under the sink, in the floor or just outside the kitchen

Large tank, usually in-ground outside or below the slab

Sized by

Peak flow rate of the fixtures draining to it

Volume and retention time

CSA standard

CSA B481.1 or B481.2

None; sized to the Building Code

Flow control device

Required, to keep flow below the rating

Not used the same way

Typical fit

Cafés, small and mid-size restaurants, single tenants

Large restaurants, food courts, plazas and buildings with several food tenants

Servicing

Frequent, often every four weeks in Toronto

Less often, but each service is a pump truck

Many fit-outs end up with a hydromechanical unit per kitchen. Larger developments and food courts often use one gravity interceptor shared by several tenants, which makes the cleaning schedule and cost split a lease issue. Our guide to grease trap cleaning in Ontario covers that side.

Precast concrete gravity grease interceptor being lowered into an excavation behind a restaurant plaza while a plumber guides it

How to size a hydromechanical grease interceptor

The common method, used in Canadian municipal guidance such as the City of Calgary's sizing handout (City of Calgary), works from the fixtures:

Plumber measuring a three-compartment sink to calculate peak flow for grease interceptor sizing
  1. List every fixture that will drain to the interceptor. Usually the pot sink, prep sinks, hand-wash sinks in the kitchen if connected, floor sinks and floor drains in cooking areas, and any equipment your designer connects.

  2. Calculate the volume of each sink compartment. Length x width x depth.

  3. Apply a fill factor. Sinks are rarely filled to the brim, so worksheets commonly assume about 75 percent of the compartment volume.

  4. Choose a drain-down time. Most methods use one minute, meaning the sink empties completely in one minute. Some allow two minutes, which halves the calculated flow but needs the drainage and the interceptor's grease retention checked.

  5. Divide the volume by the drain-down time to get the peak flow rate.

  6. Pick the next rated size up. If the result falls between two sizes, choose the larger. A unit that sees more flow than its rating passes grease through.

  7. Fit the flow control device the manufacturer specifies, so the flow can never exceed the rating.

A worked example

These numbers are illustrative only. Take a typical three-compartment pot sink with compartments of 45 cm x 45 cm x 30 cm.

  • Volume per compartment: about 61 litres. Three compartments: about 182 litres.

  • At 75 percent fill: about 137 litres.

  • Over a one-minute drain-down: about 137 litres per minute, or roughly 36 US gallons per minute. Interceptor flow ratings are commonly given in US gallons per minute.

  • Over a two-minute drain-down: roughly 18 US gallons per minute.

So the same sink points to an interceptor rated at roughly 36 US gpm or more on a one-minute basis, or about half that on a two-minute basis. Add any other fixtures draining to the same unit before choosing. This is why the sizing has to be done on your actual fixture schedule, not from a rule of thumb like "a small restaurant needs a 20 gallon trap."

Step two: check the grease capacity against your menu

Flow sizing tells you the unit will not be overwhelmed at peak. It does not tell you how fast it will fill. A café washing cups and a wing restaurant washing fryer baskets can have the same sinks and very different grease loads.

Compare the unit's rated maximum grease capacity with your expected grease load and the cleaning interval your municipality expects. In Toronto, hydromechanical units are serviced every four weeks by default, or sooner if grease and solids reach 25 percent of the liquid volume. If the unit would hit 25 percent in a week, step up a size, consider a grease recovery device, or plan a gravity interceptor. Lower-oil cooking equipment helps too, and the right fryers and filtration reduce how much oil is discarded in the first place. Elevate Service Group's sister company TFI Food Equipment Solutions supplies and services commercial fryers and kitchen equipment for exactly that reason.

Fit-out questions to ask before the plans are final

Plumber and restaurant owner reviewing kitchen plumbing drawings to plan the grease interceptor location during a fit-out
  • Is there an existing interceptor? If you are taking over a former restaurant, find out its type, size, age and condition, and whether it suits your menu. A camera inspection of the kitchen line and an inspection of the interceptor before you sign is cheap insurance.

  • Who owns it under the lease? Usually the landlord owns the interceptor as a building fixture and the tenant cleans it, but read the lease. On a shared interceptor, get the cleaning schedule and cost split in writing.

  • Where will it go? It needs to be reachable for cleaning and pump-out without carrying grease through the kitchen or dining room, and installed level with the right venting and a cleanout. An interceptor buried under equipment does not get cleaned.

  • What drains to it? Decide early which fixtures and equipment connect. Your designer and the municipal plans examiner will want this on the drawings, and some local rules restrict what can discharge upstream of an interceptor.

  • Is the drain line ready? The line from the kitchen to the interceptor and on to the main needs the right slope and cleanouts so it can be jetted. See our guide to hydro jetting vs snaking for why that matters.

  • Is the permit in the schedule? Toronto requires a building permit to install or replace an interceptor, and other municipalities have their own requirements. Leave time for it.

Grease interceptor installation with Elevate Plumbing

Elevate Plumbing, a division of Elevate Service Group, installs and replaces grease interceptors for restaurants, franchise operators and landlords, sized to the Ontario Building Code and the CSA standard, and connects the kitchen drain lines that feed them. On existing spaces we inspect the interceptor and camera the kitchen line before you commit, and once you are open we can keep the lines clear with scheduled drain cleaning.

The crew is based in New Hamburg and serves Kitchener-Waterloo, Cambridge, Guelph, London, Hamilton, Toronto and the rest of Southwestern Ontario and the GTA. For multi-site operators and property managers, the work can sit inside a commercial plumbing maintenance contract, backed by Elevate Service Group's network of more than 130 technicians across plumbing, electrical and facility services.

To plan an installation, send your kitchen layout and fixture schedule through the contact page.

Frequently asked questions

What size grease trap does a restaurant need?

It depends on the fixtures that drain to it and the menu, not the seat count. Add up the sink compartment volumes, apply a fill factor of about 75 percent, divide by a one-minute drain-down time to get the peak flow, and choose a unit rated at or above that flow. Then check its grease capacity against how much grease your kitchen produces between cleanings.

How do you calculate grease interceptor size?

For a hydromechanical unit, calculate the peak flow: total sink volume x fill factor, divided by the drain-down time, usually one minute. Choose the next rated size up and fit the specified flow control device. Gravity interceptors are sized by volume and retention time to the Ontario Building Code.

What is the Ontario Building Code requirement for grease interceptors?

The Code requires a grease interceptor where commercial food preparation discharges grease, and says a required interceptor must conform to CSA B481.1 or CSA B481.2. Sizing, selection, location and installation are covered by CSA B481.3, and municipalities add permit and sewer use requirements.

What size grease trap do I need for a three-compartment sink?

As an illustration, a three-compartment sink with 45 x 45 x 30 cm compartments works out to roughly 36 US gallons per minute on a one-minute drain-down, or about 18 on a two-minute basis. Your actual sink dimensions and any other fixtures on the same unit change the answer, so size from your fixture schedule.

What is the difference between a hydromechanical and a gravity grease interceptor?

A hydromechanical interceptor is compact, uses baffles, is sized by flow rate and certified to CSA B481.1 or B481.2. A gravity interceptor is a large tank sized by volume and retention time, with no CSA standard, and suits large kitchens and multi-tenant buildings.

Do I need a permit to install a grease interceptor?

In Toronto, yes, a building permit is required to install or replace one. Other Ontario municipalities treat it as plumbing work under the Building Code with their own permit process, and the Region of Waterloo requires food businesses discharging grease to hold a sewer use permit. Check with your municipality before work starts.

Is a bigger grease trap always better?

No. A properly sized unit is better than an oversized one. An oversized interceptor costs more, takes more space and can still need frequent cleaning if grease sits in it too long. Size to the flow, check the grease capacity against your menu and cleaning schedule, and choose the larger size only when the calculation falls between two.

Tags:

Author

Elevate Plumbing Team

Elevate Plumbing is a division of Elevate Service Group.

View all posts by Elevate Plumbing Team

Leave a comment

This will be publicly visible.

Your email address will not be published.

Your comment will be reviewed by an admin before it is published.

Related Articles

Get a quote

Need a Plumber? We’re Only a Call Away.

Request a quote and we'll get back to you within one business day. For emergencies, call us any time, day or night.

24/7 emergency service

+1 (519) 469-9797

Licensed & Fully insured

Thanks, we've got it.

We'll be in touch within one business day. Need help now? Call +1 (519) 469-9797

Return home